That's it, there is no other response from the unit. JavaScript is disabled. Could someone please confirm that I should indeed have well pump "ON"? Simply visit your local Navien wholesaler and pick up everything you need. If any particular ad is your REASON for blocking ads, please let us know. Hope this helps. Yes, I know. Support has been useless for the most part and just points to Korea Dev team. Zsoldier, he dip switches there dont get into the real detail of the programming. Navien Now Doing Business in Canada as Navien Canada, Inc. Navien Begins Shipping PeakFlowC Commercial Scale Prevention Systems. You are incorrect. Tech support is clueless. * Existing installations may require the purchase of a new main PCB and front control panel. Create an account to follow your favorite communities and start taking part in conversations. Hey there, Im Chris. Save my name, email, and website in this browser for the next time I comment. Now with a single NPE240A and the re circulation I can keep hot water to the last fixture in the home. Interesting reading these comments. Gas. Since the 210A has an internal pump, this confused me. It looks like you're using an ad blocker. My NaviLink was working just fine for about2 months. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, makes it even easier to install and set up, 2" PVC up to 75 feet and 1/2" gas up to 24 feet, High efficiency up to 0.95 UEF and up to 15:1 TDR, Durable dual stainless steel heat exchangers, EZNav multi-line control with built-in intuitive software, Problem Solved: Gandy Installations Saves Customer Enough Space for a Refrigerator, Problem Solved: Steve Hosack of SC Hosack Plumbing Upgrades His Hair Stylist to Navien, Ways to save money on your water & electric bill. 800-556-7556 or see HarryEklof.comFull Naivien information including dealer and Rep locators is available at www.navieninc.com To generate a kerbero's keytab , you simply need the name and password of a service account (this is simply a Active Directory user account) in your domain. Navien Npe 240a Review AdinaPorter from www.adinaporter.com Web the navien intracranial support catheter has a nitinol coil and proprietary polymers to deliver thin wall construction 1 that provides a large id among 5/6 fr catheters 2 while delivering improved trackability 1,2 and resistance to ovalization. Looking at the various videos before buying the Navilink router, they make it seem like the app would include a 'hot button' feature. Also I set dip switch 5 to "ON" for the well pump setting. Smarter that way, just not instant. with a wire stripper befor e connecting it to the solenoid valve. Im fairly certain this is the case. Navien NPE-240A dip switch settings help please I just got finished getting my Navien NPE-240A tankless installed. My unit is a replacement for an existing electric tank recirc loop system. Given the highly critical reviews of the NaviLink app on the Apple iOS App Store, I am reluctant to buy until I can verify that 1) re-enabling schedules using the NaviLink app is easy to do and 2) we can use the NaviLink app to activate the CP on-demand (in other words, the app does, indeed, have a software-based button). I expect that would have some positive effect on the time to deliver hot water, even if it is small. Can anyone lend some guidance as to what the recommended dip switch setting should be? If you want the heater to provide the cross over where the hot return and cold combine then set it to internal. Space-saving high-efficiency condensing boilers provide the ultimate heating and comfort experience. Still appears to have the same "Enable/Disable" terminology. Hello, You might want to talk with the folks at ACT, 714-668-1200 www.gothotwater.com. Protect the water supply and water heating equipment with eco-friendly water treatment solutions. I tried purging the line - Answered by a verified Plumber . Strong signal. This chapter will walk you through the step-by-step guide to let you learn how to use the recirculation mode. the 2 mounting screws. Replacing one NPE for two 90 gallon tanks ( one dead and one likely to die) was a cost savings even though the NPE and recirc is expensive. This Taco valve can even be cleaned easily. I agree with Spacecowboy-- The information I have refers to external recirculation with cold water line return, but I expect the settings would be the same with a dedicated return line. Part No. A tankless water heater, whether it comes from Navien or other brands, will provide you a reliable service for up to 20 years if you maintain it according to the manual. Navien NP-240A Pdf User Manuals. Lastly, press and hold down the OK button for 2 seconds to finalize the weekly schedule setting. How long do Navien tankless water heaters last? So I just got off with a "Senior" support specialist at Navien Customer support. I have a Navien NPE-240A tankless heater, . I was reading the directions, and it wants me to set the Heater to External recirculation. For more information, please see our I had a dedicated external recirculation line installed to use with the Navien internal pump. I just want to make sure my understanding is correct. The A2 is the upgrade that started shipping in March 2021. Research I've seen suggests this will save over 90% of the energy costs associated with 24 hour recirculation, which is essentially what you have. It's unfortunate he's not around to explain all this to you. External means you will be using a seperate pump, not the internal one inside the unit. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. Colector ReadyLink Hoja De Especificaciones Espanol (USA & Can NPE Guia De Conversion De Gas (USA & Canada), NPE Guia De Instalacion Rapida Espanol (USA & Canada), Navien-NPE-Series-CSI 3-Part Formatted Specifications, Ready-Link Manifold 2BB Submittal Package, Ready-Link Manifold 2SS Submittal Package, Ready-Link Manifold 3SS Submittal Package, Ready-Link Manifold 4BB Submittal Package, Ready-Link Manifold 4SS Submittal Package. Internal would mean that it recirculates the water inside the unit only. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. I don't have any answers to your questions, but I am curious to know how you like the overall setup? Once you turn that DIP switch, the water heater software will monitor the flow demands over a 7 day cycle and recirculate the water from the following week based on water usage. The house is set up with recirculation, though I am not sure where in the house the "T" on the system is located. They are top tier support and know the most. Connect the External Pump Wire to the proper wires from the. So, you must play with this setting and adjust it according to your water usage demand. Efficient, durable and high-performance products for any commercial application. Assuming you've created a Transport Node Profile and associated w/ the cluster. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, PeakFlowE Installation, Operation and Maintenance Manual, Manual De Sistema Ventilacion Comun Espanol (USA & Canada). Space-saving high-efficiency condensing boilers provide the ultimate home heating and comfort experience. But you may need to flush the unit every six months if you live in a hard water area or operate the unit at a higher temperature setting. Privacy Policy. This week we added the NaviLink to our unit (NPE-240A2). Protect the water supply and water heating equipment with eco-friendly water treatment solutions. We might be able to do something about it. The manual also has dip switch settings for "External Recirculation" but I am afraid if I set it to that setting it will not use the "intelligent computer" and run all the time. Read Also: Navien Tankless Water Heater Post Purge Navien Tankless Water Heater Standby Mode Eric Alvarez 2. The internal recirculating pump continuously keeps running. If the hot button is not engaged, or a schedule is not specified and enabled in the app then the water heater simply will not re-circulate. What I am going to discuss in this article is-. Today I opened the front panel and saw that all the dip switches were set to off. Internal with internal pump. Efficient and earth-friendly products designed for any size home. With Navien's Ready-Link cascading technology, when a unit gets up to 80% capacity the next unit will turn on to help meet requirements. Reddit and its partners use cookies and similar technologies to provide you with a better experience. Factory Setting of DIP Switch. How to use the recirculation modes on a Navien Water Heater? Any other comments/recommendations for a Navien tankless newbie are welcome! I think that by switching to External just means that we are going to be recirculating water outside of the unit. Summary: I started running into issue utilizing Cisco AnyConnect on my Mac basically complaining about not able to overwrite IP forwarding tables. For recirculation Navien is not clear as to the use of parameters. PFFW-001, NaviCirc Kit: 30022965A. Water heater without tanks, also called instant water heaters heat water immediately upon request. Navien NR-180(A); NP-180(A); NR-210(A); NP-210(A); NR-240(A); NP-240(A) Condensing Water Heater, Navien NP-240A Service Manual (179 pages), High Limit Switch or Exhaust Limit Switch, Preparing the Water Heater for Inspection, Navien NP-240A Operation & Installation Manual (89 pages), Navien NP-240A Installation Manual (78 pages), Contaminated Make-Up Air will Damage the Unit, Navien NP-240A Owner's Operation Manual (45 pages), Pump Activation Setting Function When Hot Water Is Used, "A" Series Models Built-In Circulation Function, Basic Troubleshooting and Frequently Asked Questions, Navien NP-240A Installation Manual (68 pages), Navien NP-240A Quick Installation Manual (4 pages). 20. Navien 240A Recirculation Settings. By using a kerberos keytag, I'm able to in the very least obfuscate the username and password into a file for upload into the iDRAC. Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. Yierd! Typically with tankless water heaters, the circulator needs to be properly sized. The installers insisted they did not need to pipe the recycle returnthey wanted to cap it off. Disabling schedules simply disables "recirculation", the function that keeps hot water hot in the plumbing for 'instant hot water'. I have been battling this unit for 2 years. It is not in the manual. Summary: I was looking to automate configuration of iDRAC's (Dell Remote Admin Console) synonymous w/ iLOM and many other acronyms. My pump seems to run every time I need hot water. The update is not perfect, but seems to be much more user friendly interface. If it is not on your navilink still may bridge to your phone but not commiunicate with your npe. I suspect a process issue. . Deactivate Circulator Timer and Periods. Read the user's Navien nr-240a manual to get information on how to flush the heat exchanger and how to reset remote for Navien tankless water heater. dip one off, dip 2 on, everything else off (down is off). Apple iOS Google Android NPE-240A Downloads Click here to see downloads for other products. It may not run the entire time but it does run. My 6-year-old NR-240A NR-240A weekend with E038. Attach the water supply to support recirculation. Navien Recirculation Settings have a lot of advantages. You must log in or register to reply here. But would like to have the 'instant button' in the app that I could push in the evening, where it would recirculate the water for me on demand, and then five min later I can take a hot shower. Always On: It will repeat DHW recirculation. (Dip switch settings - https://imgur.com/gallery/xRzjyRN) Did I set this up correctly? You need a crossover valve installed under one of your faucets that is far away from the water heater (there are a few different styles but they all have four connections and get installed under a faucet). They had me un-register and re-register to get it working. I kept looking at the programming trying to figure out what was wrong. MacOS: AnyConnect VPN client was unable to successfully verify the IP forwarding table modifications. New Problem - I cannot connect my NaviLink to my home wifi. Details: If you were to query the status of the cm-inventory via API or CLI, you could query all 3 manager/controller nodes and get a status of running. The app will not connect to my wifi. My home is long and used to have two water heaters, one on either side of the house. NaviLink Lite is great for single residential units and magnetically mounts to the side of the unit or can easily be mounted on the wall. I simply cannot believe the iPhone app won't allow both recirc schedule on a dedicated loop and ability to turn on/off recirc at other times. Then if that doesn't work, I would keep it at 1 minute, and then set 14 to 1 minute, and I would also try 14 at its max. I tried reconnecting using the AP button. By rejecting non-essential cookies, Reddit may still use certain cookies to ensure the proper functionality of our platform. It is compliant with California Title 24. The H2Air Kit utilizes the NPE-A2 pump to circulate the hot water for the hydronic air handler. NPE-240A2 Optional NPE-A2 recirculation valve Designed for recirculation of domestic hot water in applications where a dedicated return line is not available. Adding a "Hot button" overrides schedulers (navilink or NR-20DU). Internal will keep open the same valves but also use the internal pump as set, and not rely on any external pump. is this recirculation pump just recently installed? Basically, you add a host to a vCenter cluster, NSX-T bits should start to automatically installing on new host. Can anyone clarify? You can find this valve inside the water heater. This seems relatively new for Navien and is in a recent Navien technical bulletin from 04/18/16. I don't know the best place to post this, but i happened to be fiddling around in the NaviLink app on Feb. 1 and it asked to update. So what's going on here? Set the position of the 2-way valve, which you can find inside the water heater. Efficient, durable and high-performance products for any commercial application. 8. At the push of a button, Navien's HotButton accessory activates the internal recirculation pump and gas-fired burner to heat up the water in the supply lines. Navien 30015307A Circulation Pump, NCB-E Models OEM PART $272.95 In Stock FREE SHIPPING Navien 30002583A High Limit Switch, OEM PART $18.85 In Stock FREE SHIPPING Navien HotButton Recirc Pump Control for NPE-A Series, PZZZ-00046 $115.45 In Stock FREE SHIPPING NAVIEN 30014189B NHB FLAME ROD ASSEMBLY, OEM Part $31.38 In Stock FREE SHIPPING It was totally worth it, here is why and how to set it up. Either you select the Internal Recirculation Mode or the External Recirculation Mode, both these modes has three common recirculation loops: However, the External Recirculation mode has an additional recirculation loop called HotButton, which takes it apart from Recirculation mode. 3. On the App, the Enable button appears and is highlighted and now controls the times I have programmed for on/off. I'm going to install the Navicirc tomorrow when i have a few minutes. 1. Designed for recirculation of domestic hot water in applications where a dedicated return line is not available. Looks fine, Y U NO WORK!? Our fancy NPE-240A2 was installed yesterday with Navilink. Press either the Up and the Down button to switch between any of these recirculation settings: 3. We are on well water and have a low flowing well. The control is recirculation only. Below assumes the iDRAC has been configured and is available on the network in default config. If you'd like to support the site, please allow ads. There is always an interval between when water is called for and the start of the burner. I have even had to swap out control and front panel boards to get the function to work, but they broke that with an app update. Hoja de Especificaciones Sistema de Ventilacin para Exteriore Hoja de Especificaciones Cable para Bomba Externa NPE, Hoja de Especificaciones Calentadores de Agua sin Tanque serie NPE, Hoja de Especificaciones Sistema HotButton, NPE Outdoor Vent Kit Spec Sheet (USA & Canada), NPE Series Specification Sheet (USA & Canada), Problem Solved: Gandy Installations Saves Customer Enough Space for a Refrigerator, Problem Solved: Steve Hosack of SC Hosack Plumbing Upgrades His Hair Stylist to Navien, Ways to save money on your water & electric bill. A place for plumbing advice and help. Navien water heaters are highly efficient tankless water heating systems. NPE-240A Downloads Download the new Navien mobile app! https://www.amazon.ca/dp/B0752P57ZG/ref=as_li_ss_tl?keywords=ewelink+module&language=en_US&ie=UTF8&sr=8-1&linkCode=gs2&linkId=7b93392fcd98392bd94c34a45a30dfb2&tag=twhomeshow07-20. NSX-T: vCenter and NSX-T Inventory out of Sync (Hosts in vSphere not showing up in NSX-T), Disconnect NR-20DU remote controller. (Internal Recirculation would be the opposite), Parameter 18 set to On (This is to enable. This was on 4.6.x. It looks like you're using an ad blocker. Also, NaviLink Lite does not require external power. Go along the steps described below to set the recirculation settings. Error Code E046 There is something wrong with limit control. I thought we could re-use the remote controller (NR-10DU) from our old NPE-180A but it does not work with this. 6. Press either the Up or the Down button to choose the scheduled time. For a better experience, please enable JavaScript in your browser before proceeding. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. Protect your water supply and your water heating equipment with eco-friendly water treatment solutions. ktpass /pass ReallySecurePas5word /ptype K, The VPN client was unable to successfully verify the IP forwarding table modification. How To Set Recirculation Mode On Navien Water Heater? After much frustration getting the app installed and setting a schedule, we are unsure whether the app is actually communicating with the unit according to the schedule. During this delay gases are blown out of the exhaust and cold-water flows through the burner unheated leading later to a cold-water sandwich. . a faucet is open) and no recirculation is occuring? Eventually, I want to run a return line from the kitchen area back to the hot water heater and that should significantly reduce the delivery time, since all the faucets feed off the line that leads to the kitchen. Adding a "Hot button" overrides schedulers (navilink or NR-20DU). What follows is a journey into a ridiculous realm. Say with external pump being used function, if your recirculation line connects together outside of the heater like with an actual return line then set it external. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Navien 240A Dip Switch Settings [Explained Everything] Every Navien Tankless Model, either 240A or 180A2, has two DIP switch locations. I would make my back steps half of the known good/bad settings to speed up the search process. A VPN connection will not be established. I had a dedicated external recirculation line installed to use with the Navien internal pump. that fan will come on when water is called for and go off a bit after the call has stopped. I too have the NPE-240A, and this is what was explained to me. With the -A uinits (with the recirculation pump) does that pump have to run to supply on demand hot water? So disabling and enabling the schedule does not work as a workaround to the hot button feature not showing up except for the fact that when enabled it will find that the reservoir temp is lower than it should be and begin to heat it, which then in turn will allow it to start to recirculate again (not time saving or water saving at all). Navien 240a Tankless Water Heater from hybridwaterheater.blogspot.com. Am I correct in assuming this means that the internal loop and buffer tank only heat up when there is there is demand for hot water (i.e. Space-saving high-efficiency condensing boilers provide the ultimate home heating and comfort experience. What I have found to keep it easy for understanding the schedule enable/disable on the appis to add the letter "d" at the end of the word being displayed. Is there a link that I can find this parameter table at? Just want to say thanks for everyone that has commented thus far. This gives users hot water when they need it, saving water and money. This removes the need to purchase an additional circulator for the heating system. I, recently had a Navien NPE-240A unit installed. But I think I've figured out the nomenclature. We are on well water and have a low flowing well. Navien Recirculation Settings have a lot of advantages. external recirculation pump. "If you can't explain it simply, you don't understand it well enough". The app is not the most intuitive. https://www.navieninc.com/downloads/npe-a-s-manuals-installation-manual-en. Even if the primary node associated w/ the VIP, if configured, is not necessarily in charge of inventory. I have even turned off the scheduling function cause it's wasteful if I'm not around and forget to turn it off. Thanks. Naviens patented ComfortFlow system is the first to include a buffer tank, recirculation pump and fine-tuned controls into a tankless water heater, resolving the cold-water sandwich effect* and issues of minimal flow rates commonly found in other tankless water heaters. 2. Cause is unknown. To exit the view information mode, just press the back button on the front panel. We have a Navien NPE-240A boiler and an electrical (unconnected) hot water tank that acts as a storage tank. The flow on demand ratio will continue until all32 units are generating hot water as needed. They understand systems like this and can help you choose the right pump and control that only recirculates when you tell it to. Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. I got the same problem that I can not connect the Navilink to home wi-fi. I'm interested in this as well. I have had the system for a number of months now and overall I really like it. Then disconnected for unknown reasons. I pushed the little lever inside the unit down to use the external line. To make sure that the model has this feature, you simply need to check to see if there is an 'A' at the end of the model number. Hi therejust curious since I was considering a Navien 240A. Also, you can use the Navien Intelligent Preheating feature. Workaround: Restart the cm-inventory service on each NSX-T mgmt/controller node using API or CLI. The Navien cascading system also balances out the workload of each unit for longer life.